Multiscene Fluke 5700A Multifunction Calibrator Durable 600 MHz

Ask Latest Price
Video Channel
Brand Name :Fluke
Model Number :5700A
Certification :FCC
Place of Origin :USA
MOQ :1 set
Price :Negotiation
Payment Terms :T/T
Supply Ability :in stock
Packaging Details :carton
Product name :Multi Product Calibrator
Amplitude Signals :up to 600 MHz
Repair Support :Calibration only
Calibration Support :Contact us
Condition :Pre-Owned
Functions :Tested, in Full Working Conditions
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Fluke 5700A High Performance Multi-product Calibrator

Description of Fluke 5700A Multi Product Calibrator

The 5700A is a five-function calibrator designed to address the most demanding electrical calibration workload. They source direct and alternating voltage and current and resistance. A wideband voltage option extends overall ac bandwidth to 10 Hz to 30 MHz. Both are compatible with the 5725A, and 5205A/5215A amplifiers. Since its introduction in 1988, the 5700A has earned a worldwide reputation for performance, dependability and quality, and as a result it is the calibrator of choice throughout government and industry.

DC Voltage

  • Ranges: 0 to ±1100V
  • 5700A Best 1 Year Specification: ±7.0 ppm of setting

AC Voltage Ranges:

  • 220 mV to 1100V
  • 10 Hz to 1 MHz
  • 5700A Best 1 Year Specification: ±75.0 ppm of setting

Resistance Ranges:

  • 0 to 100 MW, 18 values in x1 and x1.9
  • 5700A Best 1 Year Specification: ±12.0 ppm

DC Current Ranges:

  • 0 to Û2.2A (11A with 5725A)
  • 5700A Best 1 Year Specification: Û50 ppm of setting

AC Current Ranges:

  • 9 mA to 2.2A (11A with 5725A) 10 Hz to 10 kHz
  • 5700A Best 1 Year Specification: ±140 ppm of setting
Technical Specifications
Voltage DC
Range: 0 to ±1100V
5700A Best 1 Year Specification: ±7.0 ppm of setting
5720A Best 1 Year Specification: ±3.5 ppm of setting
Voltage AC
Range: 0.22 µV to 1100V
10 Hz to 1 MHz
5700A Best 1 Year Specification: ±75.0 ppm of setting
5720A Best 1 Year Specification: ±45.0 ppm of setting
Resistance
Range: 0 to 100 MΩ, 18 values in x1 and x1.9
5700A Best 1 Year Specification: ±12.0 ppm
5720A Best 1 Year Specification: ±8.5 ppm
Current DC
Range: 0 to ±2.2A (11A with 5725A)
5700A Best 1 Year Specification: ±50 ppm of setting
5720A Best 1 Year Specification: ±35 ppm of setting
Current AC
Range: 9 µA to 2.2A (11A with 5725A) 10 Hz to 10 kHz
5700A Best 1 Year Specification: ±140 ppm of setting
5720A Best 1 Year Specification: ±120 ppm of setting
Wideband AC Voltage Option
Range: 300 µV to 3.5V
10 Hz to 30 MHz
5700A Best 1 Year Specification: ±0.4% of setting
5720A Best 1 Year Specification: ±0.4% of setting
General Specifications
Warm up Time
2x the time since last warmed up, to a maximum of 30 minutes
System Installation
Rear output configuration and rack-mount kit available
Interfaces
IEEE-488, RS-232, 5725A, 5205A or 5215A, 5220A, phase lock in (BNC), phase reference out (BNC)
Temperature Performance
Operating: 0°C to 50°C
Calibration: 15°C to 35°C
Storage: -40°C to 75°C
Relative Humidity
Operating: < 80% to 30°C, < 70% to 40°C, < 40% to 50°C
Storage: < 95%, non-condensing. A power-on stabilization period of four days may be required after extended storage at high temperature and humidity.
Safety
Designed to comply with UL311; IEC 348-1978; IEC 66E (CO)4; CSA 556B
Guard isolation
20 volts
EMI/RFI
Designed to comply with FCC Rules Part 15, Subpart J, Class B; VDE 0871, Class B
Line Power
47 to 63 Hz; + 10% allowed about selectable nominal line voltage: 100V, 110V, 115V, 120V, 200V, 220V, 230V, 240V
--------------
Maximum power: 5700A/5720A: 300 VA;5725A, 750 VA
Calibration Documentation 17025 accredited report of calibration included
Size
5700A/5720A: Height 17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet; width 43.2 cm (17 in), standard rack width; depth 63.0 cm (24.8 in) overall; 57.8 cm (22.7 in), rack depth
5725A: Height 13.3 cm (5.25 in); width and depth same as 5700A/5720A
Both units project 5.2 cm, (2 in) from rack front
Weight
5700A/5720A: 27 kg (62 lbs.)
5725A: 32 kg (70 lbs.)

List of Options

Options
03 Wideband AC Voltage Module
EP UPGRADED FROM A 5700A
NAF-03 NAF version with 03 wideband AC Voltage


Multiscene Fluke 5700A Multifunction Calibrator Durable 600 MHzMultiscene Fluke 5700A Multifunction Calibrator Durable 600 MHzMultiscene Fluke 5700A Multifunction Calibrator Durable 600 MHz


FAQ:

1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .

Inquiry Cart 0